No products
View larger New product
1.1 This test method is intended to evaluate the performance of virgin, newly impregnated or in-service, granular or pelletized activated carbon for the removal of hydrogen sulfide from an air stream, under the laboratory test conditions described herein. A humidified air stream containing 1 % (by volume) hydrogen sulfide is passed through a carbon bed until 50 ppm breakthrough of H2S is observed. The H2S adsorption capacity of the carbon per unit volume at 99.5 % removal efficiency (g H2S/cm3 carbon) is then calculated. This test is not necessarily applicable to non-carbon adsorptive materials.
| Author | ASTM |
|---|---|
| Editor | ASTM |
| Document type | Standard |
| Format | File |
| Confirmation date | 2014-08-15 |
| ICS | 19.020 : Test conditions and procedures in general 71.040.30 : Chemical reagents |
| Number of pages | 9 |
| Replace | ASTM D6646-03(2008) |
| Set | ASTMVOL1501 |
| Year | 2003 |
| Document history | ASTM D6646-03(2008) |
| Country | USA |
| Keyword | ASTM 6646;ASTM D6646;ASTM D6646;10.1520/D6646-03R14 |