1.1 This practice describes procedures, soils, and soil placement for the proper installation of corrugated aluminum culverts and storm sewers in either trench or projection installations. A typical trench installation is shown in Fig. 1, and a typical embankment (projection) installation is shown in Fig. 2. The pipes described in this practice are manufactured in a factory and furnished to the job in lengths ordinarily from 10 to 30 ft [3 to 9 m], with 20 ft [6 m] being common, for field joining. This practice applies to structures designed in accordance with Practice B790/B790M.
| Author | ASTM |
|---|---|
| Editor | ASTM |
| Document type | Standard |
| Format | File |
| Confirmation date | 2014-05-01 |
| ICS | 91.140.80 : Drainage systems |
| Number of pages | 5 |
| Replace | ASTM B788/B788M-09 |
| Set | ASTMVOL0202 |
| Year | 2009 |
| Document history | ASTM B788/B788M-09 |
| Country | USA |
| Keyword | ASTM 788;ASTM B788;ASTM B788;10.1520/B0788_B0788M-09R14 |