1.1 This test method details a procedure for performing particle size distribution analysis by dry sieve testing on green petroleum coke with a topsize of no more than 75 mm and calcined petroleum coke with a topsize of no more than 25 mm. Size fractions go down to and include 4.75 mm for green petroleum coke and 75 μm for calcined petroleum coke.
Note 1: To convert units, see Table 1 on nominal dimensions in Specification E11. For example, 75 mm is approximately equivalent to a nominal sieve opening of 3 in. and 25 mm to a nominal sieve opening of 1 in. Likewise, 4.75 mm can be converted to approximately 0.187 in. and 75 microns to 0.0029 in.
| Author | ASTM |
|---|---|
| Editor | ASTM |
| Document type | Standard |
| Format | File |
| Confirmation date | 2015-10-01 |
| ICS | 75.160.10 : Solid fuels |
| Number of pages | 4 |
| Replace | ASTM D5709-09 |
| Set | ASTMVOL0502 |
| Year | 2009 |
| Document history | ASTM D5709-09 |
| Country | USA |
| Keyword | ASTM 5709;ASTM D5709;ASTM D5709;10.1520/D5709-09R15 |