1.1 These test methods cover the determination of the flash point of petroleum products in the temperature range from 40 °C to 370 °C by a manual Pensky-Martens closed-cup apparatus or an automated Pensky-Martens closed-cup apparatus, and the determination of the flash point of biodiesel in the temperature range of 60 °C to 190 °C by an automated Pensky-Martens closed cup apparatus.
Note 1: Flash point determinations above 250 °C can be performed, however, the precision has not been determined above this temperature. For residual fuels, precision has not been determined for flash points above 100 °C. The precision of in-use lubricating oils has not been determined. Some specifications state a D93 minimum flash point below 40 °C, however, the precision has not been determined below this temperature.
| Author | ASTM |
|---|---|
| Editor | ASTM |
| Document type | Standard |
| Format | File |
| ICS | 13.220.40 : Ignitability and burning behaviour of materials and products 75.080 : Petroleum products in general 75.160.20 : Liquid fuels |
| Number of pages | 18 |
| Replace | ASTM D93-16a + Redline |
| Set | ASTMVOL0501 |
| Year | 2018 |
| Document history | ASTM D93-16a + Redline |
| Country | USA |
| Keyword | ASTM 93;ASTM D93;ASTM D93;10.1520/D0093-18 |