1.1 This test method covers the evaluation of the oxidation stability of inhibited steam-turbine oils in the presence of oxygen, water, and copper and iron metals at an elevated temperature. This test method is limited to a maximum testing time of 10 000 h. This test method is also used for testing other oils, such as hydraulic oils and circulating oils having a specific gravity less than that of water and containing rust and oxidation inhibitors.
| Author | ASTM |
|---|---|
| Editor | ASTM |
| Document type | Standard |
| Format | File |
| ICS | 75.100 : Lubricants, industrial oils and related products |
| Number of pages | 11 |
| Replace | ASTM D943-17 + Redline |
| Set | ASTMVOL0501 |
| Year | 2018 |
| Document history | ASTM D943-17 + Redline |
| Country | USA |
| Keyword | ASTM 943;ASTM D943;ASTM D943;10.1520/D0943-18 |